ADC-2522 Air Data Test Calibrator

ADC-2522 Front Panel ADC-2522 Rear Panel  Sperry Honeywell ADT-222B Replacement

ADC-2522

The ADC-2522 is built on TestVonics ADC-2550 series platform. It is designed for rackmount use and features a large 10.4" display with resistive touchscreen. The calibrator is designed with a Honeywell Sperry IEEE-488-1975 emulator. This allows the calibrator to be a plug and play replacement for the aging Honeywell ADT-222B Air Data Test System and similar test sets without having to modify existing communication protocols or software.
  • High Precision Air Data Test Calibrator (ADT-C) and ADT-222B replacement
  • Replaces ADT-222B NSN: 4920-01-105-0016 and Model No. 4047505-422 and 4047505-421
  • Intuitive Graphical User Interface
  • Designed for ATE - features plug and play Honeywell Sperry emulation
  • USB, RJ-45, RS-232, IEEE-488.2 Interfaces
Features
The ADC-2522 features a high resolution 10.4-inch LED back-lit LCD display with integrated touchscreen. The expansive display allows for an uncluttered and intuitive software interface. A front panel mounted stylus allows the operator to interact and control the calibrator directly from the front panel. Additionally, a USB keyboard and mouse are included as a secondary input source. The calibrator uses two (2) high precision, non-density sensitive transducers, which provide unmatched accuracy and performance. Corrections are done through software, requiring no mechanical adjustments, and are capable of holding their accuracy for a period of at least one (1) year.

Simple Intuitive Interface
The ADC-2522 software provides a familiar and intuitive graphical user interface for any operator. The calibrator measures and record readings and displays the data in table format or graphically in real-time. Each session is automatically saved and stored on the calibrator. This file can be printed for calibration reports and records and backed up to a network or removable media. In addition, the calibrator can be operated remotely through the RS-232 (serial) located on the rear panel. The ADC-2522 also includes an IEEE-488 interface, with backwards support for legacy Honeywell ADT-222B Air Data Test System interface. This interface allows for a plug and play solution for systems such as the ADT-222B ( NSN: 4920-01-105-0016 and P/N:: 4047505-422 and 4047505-421 ) and ADT-222C systems. The ADC-2522 operating system platform is designed for expandability through software updates, allowing it to be adaptable to future test requirements.
Safety and Protection
The ADC-2522 incorporates several hardware and software measures to protect the air data calibrator and the device under test (DUT). The ADC-2522 features input pressure regulation, over-range, over-limit and over-pressurization protection. 5 micron micro-porous filters and screening prevent debris from entering the system. The calibrator is also equipped with pressure relief valves to protect the pneumatic system components and the DUT from damage caused by excessive pressures. The front panel manual vent valve is used to accelerate venting of the Ps manifold to ambient pressure. ADC-2522 software is designed with limit exceedances and settings, providing additional safety to the DUT. Software is designed to prompt and warn the user when pressure ranges exceed the limitations of the test set. Test Profiles can be set up for different test applications so that users are not required to manually enter set points and tolerance each time.